Some preloading content here
Header of Tecnolux: outdoor lighting, recessed lighting, led lights, architectural lighting and neon tubes.
Visit Video Section Email Site Map Tecnolux.ru  
   Home arrow Electronic Converters | Outdoor Lighting Fixture arrow CONTROL GEAR and DMX Controllers- Lighting Application
CONTROL GEAR and DMX Controllers- Lighting Application

Non-dimmable Converters

Code
Certification
V min-max1)
POWER (watts)3)
In (A)
Power Factor
Hz 2)
Lamps
per
converter
Volt
mA
TB ECG 900-100
CE
230
50
0,25 5)
0,99
19
1
900
100
Midi ECG 900-100
CE
230
50
0,25 5)
0,99
19
1
900
100
TB ECG 900-180
CE
230
85
0,35 5)
0,99
19
1
900
180
Midi ECG 900-180
CE
230
85
0,35 5)
0,99
19
1
900
180
TB 900-180-K
230
80
0,8 5)
0,55
19
1
900
180
Midi 900-180-K
230
80
0,8 5)
0,55
19
1
900
180
TwoLite 960-ND
CE
230
65
0,3
0,95
24
2 4)
2 x 900
60
TwoLite 900-100-ND
CE
230
80
0,4
0,95
24
2 4)
2 x 900
100
TwoLite ECG 960
CE
230
70
0,3 5)
0,99
19
2 4)
2 x 900
60
TwoLite 960-K
230
70
0,6 5)
0,55
19
2 4)
2 x 900
60
TwoLite ECG-900-100
CE
230
90
0,4 5)
0,99
19
2 4)
2 x 900
100
TwoLite 900-100-K
230
90
0,7 5)
0,55
19
2 4)
2 x 900
100

1) Mains 230V ±10% Hz. 50/60
3) Max Load Wattage
4) These models may be used as lamps supports
5) Inrush current 3xIn.
6) Indicative lamp dimension: lenght 200cm, Ø 18 mm. (6,6 feet, Ø 0,70 inches)


Dimmable with Phase Control Converters

Code
Certification
V min-max1)
POWER (watts)3)
In (A)
Power Factor
Hz 2)
Lamps
per
converter
Volt
mA
TB 900-100
CE
230
40
0,2
0,95
24
1
900
100
Midi 900-100
CE
230
40
0,2
0,95
24
1
900
100
TB 900-180
CE
230
90
0,4
0,95
24
1
900
180
Midi 900-180
CE
230
90
0,4
0,95
24
1
900
180
TB 900-180-120V
CE
120
90
0,8
0,95
24
1
900
180
Midi 900-180-120V
CE
120
90
0,8
0,95
24
1
900
180
TwoLite 960
CE
230
65
0,3
0,95
24
24)
2 X 900
60
TwoLite 900-100
CE
230
80
0,4
0,95
24
24)
2 X 900
100

1) Mains 230V ±10% Hz. 50/60
3) Max Load Wattage
4) These models may be used as lamps supports
5) Inrush current 3xIn.
6) Indicative lamp dimension: lenght 200cm, Ø 18 mm. (6,6 feet, Ø 0,70 inches)
Complies with EMC Safety Standard EN 61347-2-10Complies with EMC Emission Standard EN 55015Complies with EMC Immunity Standard EN 61547Complies with EMC Limits for harmonic current emissions EN 61000-3-2



DMX Dimmable Converters

Code
Certification
V min-max1)
POWER (watts)3)
In (A)
Power Factor
Hz 2)
Lamps
per
converter
Volt
mA
TwoLite ECG-900-100-PWM
CE
230
90
0,4 5)
0,99
19…80
2
900
100
ThreeLite ECG 960-PWM
CE
230
130
0,55 5)
0,99
19…80
3
900
60
ThreeLite ECG 960-DMX
CE
230
130
0,55 5)
0,99
19…80
3
900
60
FourLite ECG 950-PWM
CE
230
130
0,55 5)
0,99
19…80
4
900
50
FourLite ECG 950-DMX
CE
230
130
0,55 5)
0,99
19…80
4
900
50

5) Inrush current 3xIn.
7) PWM = DMX compatible with PWM Interface
8) DMX = Converter with built-in DMX Receiver


Dimmable 1-10 V Converters

Code
Certification
V min-max1)
POWER (watts)3)
In (A)
Power Factor
Hz 2)
Lamps
per
converter
Volt
mA
TB ECG 900-100 RD
CE
230
50
0,25 5)
0,99
19…80
1
900
100
Midi ECG 900-100 RD
CE
230
50
0,25 5)
0,99
19…80
1
900
100
TB ECG 900-180 RD
CE
230
85
0,35 5)
0,99
19…80
1
900
180
Midi ECG 900-180 RD
CE
230
85
0,35 5)
0,99
19…80
1
900
180
TB 900-180-K RD  
230
80
0,8 5)
0,55
19…80
1
900
180
Midi 900-180-K RD  
230
80
0,8 5)
0,55
19…80
1
900
180
TwoLite ECG 960 RD
CE
230
70
0,3 5)
0,99
19…80
2 4)
900
60
TwoLite 960-K RD
230
70
0,6 5)
0,55
19…80
2 4)
900
60
TwoLite ECG-900-100 RD
CE
230
90
0,4 5)
0,99
19…80
2 4)
900
100
TwoLite 900-100-K RD
230
90
0,7 5)
0,55
19…80
2 4)
900
100

1) Mains 230V ±10% Hz. 50/60
2) Frequency may vary depending upon the dimmer
3) Max Load Wattage
4) These models may be used as lamps supports
5) Inrush current 3xIn.
6) Indicative lamp dimension: lenght 200cm, Ø 18 mm. (6,6 feet, Ø 0,70 inches)




DMX-based Controllers


 
ADELIS
   
Power Supply 9…15 Vdc
Current 300 mA
DMX Outputs 6 Channels
Max. Number of DMX interfaces 32
Size 4 DIN
  DIN-rail (EN50022-35)
Features 60 Preset Colours
  Intuitive Set-up and Operation
  LCD Screen for Information
Remote Control included (9 V)  
   

ADELIS-Plus
Power Supply 230 V
Current 50 mA max.
DMX Outputs 6 Channels
PWM Outputs 6 Channels
Max. Number of DMX interfaces 32
Max. Number of PWM interfaces 5
Size 9 DIN
  DIN-rail (EN50022-35)
Features 110 Preset Colours
  Intuitive Set-up and Operation
  LCD Screen for Information
  Built-in Relay 1)
Remote Control included (9 V)  
1) the provided cutoff Relay will switch off supply
to Adelis-Plus in one minute after power-off
Power Supply and DMX>PWM Interface
 


Power Supply and DMX>PWM Interface


 
Alim9 (Power Supplies)
Power Supply 230 V
Current 100 mA max
Output Voltage 9…15 Vdc
Maximum Current 800 mA
Size 4 DIN
  DIN-rail (EN50022-35)
Features Short Circuit Protection by Fuse

Synchro PWM (Interface DMX>PWM)
Power Supply 9…15 Vdc
Current 35 mA + 5 mA for each PWM Interface
Input Signal DMX512
Output Signal 6 canali
Max. Number o+A73f PWM Interfaces 15
Size 2 DIN
  DIN-rail (EN50022-35)
Setup DMX Address by Rotary Switch


High Inductive Load Dimmers (Magnetic Transformers)



FEATURES
Power Supply  Triphase 400V + Neutral/Monophase 230 V
Frequency 50 Hz
Dimming System Leading Edge by Trial
Weight 15 Kg
Fixing System Rack 19 "
Outputs 4 Channels
Size 440x350x130
   

   
DIM-EURORES 430
Max. Current for Each Output 20 A Inductive 2)
Control Signals DMX 512/0-10 V
Features 110 Preset Colours
  Intuitive Set-up and Operation
  LCD Screen for Information
Remote Control included (9 V) Built-in Relay 1)
   

   
DIM-EURORES 430 SEMP
Max. Current for Each Output 20 A Inductive 2)
Control Signals DMX 512/0-10 V
Features LCD Screen for Information
   

   
DIM-EURORES 415 SEMP
Max. Current for Each Output 9 A Inductive 3)
Control Signals DMX 512/0-10 V
Features LCD Screen for Information




1) the provided cutoff Relay will switch off supply to Adelis-Plus in one minute after power-off
2) 25 A Max. with Resistive Load
3) 12 A M+A86ax. with Resistive Load
   

 
< Prev