Some preloading content here
Header of Tecnolux: outdoor lighting, recessed lighting, led lights, architectural lighting and neon tubes.
Visit Video Section Email Site Map Tecnolux.ru  
   Home arrow Electrodes | Cove Lighting arrow Pirex glass
Pirex glass
Type Pyrex Operating Current Dimensions
Glass
A D
mm. mm.
EB10/25 X 25 mA 96 12,0
EB12/25 C X 30 mA 96 13,5
EB12/40 C X 40 mA 110 13,5
EB15/40 C X 40 mA 100 16,0
EB15/60 C X 60 mA 110 16,0
EB18/75 C X 60 mA 124 18,0
EB18/90 C X 75 mA 124 18,0
EB18/120 C X 100 mA 124 18,0
EB18/150 C X 125 mA 124 18,0
             
C = Ceramic and Mica with loop connection
CX = Ceramic and Mica with screw connection
  Initial Current Maximum Current  
Type mA. mA.  
   
10/25 150 300  
12/25 150 300  
12/40 200 400  
15/40 200 400  
15/60 250 500  
18/75 250 600  
18/90 300 700  
18/120 350 800  
18/150 400 900  
 

Evacuate unit to be bombarded to 0.1 mbar. Add 2 to 4 mbar of air and maintain a pressure of 2 to 4 mbar throughout bombarding process.
Operating current of the bombarder should not exceed 10 times the electrode rated operating current.
Do not reduce the pressure below 1 mbar during the bombarding process.
Stop when electrode shells are glowing cherry red over the entire surfaceand glass temperature is at 220°C.

 